SZ21040416B02_JieLi_AC6XXX _BQB RF PHY
TEST REPORT
APPLICANT : ZHUHAI JieLi Technology Co. , Ltd
PRODUCT NAME : AC6XXX, AC7XXX, AC8XXX
MODEL NUMBER : AC6XXX, AC7XXX, AC8XXX
BRAND NAME : JL
BLUETOOVERSIONTH : 5.3
STANDARD(S) : BRluF-ePtoHotYhTLSowp1E5nergy RF-PHY Test Specification
RECEIPT DATE : 2021-05-14
TEST DATE : 2021-05-14 to 2021-06-01
ISSUE DATE : 2021-07-13
Edited by: Li LinBin( Rapporteur)
Approved by: Li Dong (Supervisor)
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co. , Ltd. , the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
DIRECTORY
- IDENTIFICATION SUMMARY ............................................................................................................................... 3
1.1. Test Laboratory ...............................................................................................................................................3
1.2. Client .................................................................................................................................................................4
1.3. Manufacturer ................................................................................................................................................... 4
1.4. Implementation Under Test ( IUT) .................................................................................................................4
1.5. Testing Environment ...................................................................................................................................... 4
1.6. Test condit ions: ...............................................................................................................................................4 - IUT CONFORMANCE STATUS ............................................................................................................................... 5
- STATIC CONFORMANCE SUMMARY...................................................................................................................5
- DYNAMIC CONFORMANCE SUMMARY .............................................................................................................. 5
- TEST RESULT LIST...................................................................................................................................................6
Annex A . PICS & IXIT .......................................................................................................................................... 13
Annex B . TEST SYSTEM ................................................................................................................................... 19
Annex C . TEST SETUP ...................................................................................................................................... 19
Annex D . EUT PHOTO ........................................................................................................................................20
| Change History | ||
|---|---|---|
| Version | Date | Reason for change |
| 1.0 | 2021-07-13 | First edition |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
1 . IDENTIFICATION SUMMARY
1 . 1 . Test Laboratory
| Name: | Shenzhen Morlab Communications Technology Co. , Ltd. |
|---|---|
| Address: | 1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road,Zone 67 , Baocheng, Bao’an District, ShenZhen , GuangDong, China |
| City: | Shenzhen |
| Postal code: | 518101 |
| Country: | P. R. China |
| Telephone: | +86 0755 36698555 |
| Fax: | +86 0755 36698525 |
| URL: | www.morlab.cn |
Competences and guarantees:
Morlab is a testing laboratory competent to carry out the tests described in this report.
In order to assure the traceability to other national and international laboratories, Morlab has a calibration and maintenance programme for its measuring equipment.
Morlab guarantees the reliability of the data presented in this report , which is the result of measurements and tests performed to the item under test on the date and under the conditions stated on the report and is based on the knowledge and technical facilities available at Morlab at the time of execution of the test.
Morlab is liable to the client for the maintenance by its personnel of the confidentiality of all information related to the item under test and the results of the test.
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
1 .2 . Client
| Name: | ZHUHAI JieLi Technology Co. , Ltd |
|---|---|
| Address: | 333 Kexing Rd. ,Xiangzhou Dist. , Zhuhai,Guangdong,China |
1 .3 . Manufacturer
| Name: | ZHUHAI JieLi Technology Co. , Ltd |
|---|---|
| Address: | 333 Kexing Rd. ,Xiangzhou Dist. , Zhuhai,Guangdong,China |
1 .4 . Implementation Under Test ( IUT)
| Hw version: | 1.00 |
|---|---|
| Sw version: | 1.00 |
| Description of IUT: | This is a Bluetooth dual module 5.3 |
| Sampling method: | Samples undergoing test have been selected by: the client |
| Internal Control No.: | Element: | BT_ADD: |
|---|---|---|
| 1# | 1PCS | 123456563412 |
1 .5 . Testing Environment
| PICS: | See annex A |
|---|---|
| Test Results reference: | See item 5 |
| Retention date for log reference: | 2 years |
| Test Requested | Bluetooth RF conformance testing |
1 .6 . Test conditions:
NOMINAL
| TEMPERATURE IN THE RANGE 15ºC TO 35 ºC RELATIVE HUMIDITY IN THE RANGE 20% TO 75 % | YES YES |
|---|
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| AIR PRESSURE IN THE RANGE 86 kPa TO 106 kPa | YES |
|---|
2 . IUT CONFORMANCE STATUS
This IUT has the following conformance status according to the referenced ATS specification(s) .
| Static Conformance errors? | NO |
|---|---|
| Dynamic Conformance errors? | NO |
Number of test cases run
| PASSED: | 47 |
|---|---|
| Failed: | 0 |
| Total: | 47 |
3 . STATIC CONFORMANCE SUMMARY
The PICS(s) for this IUT is consistent with the static conformance requirements in the referenced base specification(s) .
The qualified PICS/ PIXIT menu of the test system was defined in accordance with the client.
4 . DYNAMIC CONFORMANCE SUMMARY
The test campaign did NOT reveal errors in t he IUT.
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
5 . TEST RESULT LIST
| Transmitter Tests (TRM-LE) | |||||
|---|---|---|---|---|---|
| Test Case ID | Temperat | Voltage | Verdict | Test Ececut ion Date | Test Equipment Platform |
| RF-PHY/TRM/ BV-01-C Output power | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-03-C In-band emissions | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-05-C Modulation characteristics | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-06-C Carrier frequency offset and drift | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-08-C In-band emissions at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-09-C Stable Modulation Characteristics at 1 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-10-C Modulation Characteristics at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-11-C Stable Modulation Characteristics at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-12-C Carrier frequency offset and drift at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-13-C Modulation Characteristics, LE | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMS RTSB-A Test |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| Coded (S=8) | System | ||||
|---|---|---|---|---|---|
| RF-PHY/TRM/ BV-14-C Carrier frequency offset and drift, LE Coded (S=8) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-15-C Output power, With Constant Tone Extension | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-16-C Carrier frequency offset and drift, uncoded data at 1 Ms/s, Constant Tone Extension | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ BV-17-C Carrier frequency offset and drift at 2 Ms/s, Constant Tone Extension | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ PS/ BV-01-CTx Power Stability, AoD Transmitter at 1 Ms/s with 2 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ PS/ BV-02-CTx Power Stability, AoD Transmitter at 1 Ms/s with 1 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ PS/ BV-03-CTx Power Stability, AoD Transmitter at 2 Ms/s with 2 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ PS/ BV-04-CTx Power Stability, AoD Transmitter at 2 Ms/s with 1 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ASI/BV-05-C Antenna switching integrity, AoD Transmitter at 1 Ms/s with 2 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ASI/BV-06-C Antenna switching integrity, AoD Transmitter at 1 Ms/s with 1 µs | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| Switching Slot | |||||
|---|---|---|---|---|---|
| RF-PHY/TRM/ASI/BV-07-C Antenna switching integrity, AoD Transmitter at 2 Ms/s with 2 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/TRM/ASI/BV-08-C Antenna switching integrity, AoD Transmitter at 2 Ms/s with 1 µs Switching Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| Receiver Tests ( RCV-LE) | |||||
| Test Case ID | Temperat | Voltage | Verdict | Test Ececut ion Date | Test Equipment Platform |
| RF-PHY/ RCV/ BV-01-C Receiver sensitivity | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-03-CC/ I and receiver selectivity performance | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-04-C Blocking performance | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-05-C Intermodulation performance | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-06-C Maximum input signal level | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-07-C PER Report Integrity | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-08-C Receiver sensitivity at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-09-C C/ I and Receiver Selectivity | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMS RTSB-A Test |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| Performance at 2 Ms/s | System | ||||
|---|---|---|---|---|---|
| RF-PHY/ RCV/ BV-10-C Blocking performance at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-11-CIntermodulation performance at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ BV-12-C Maximum input signal level at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-13-C PER Report Integrity at 2 Ms/s | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-14-C Receiver Sensitivity at NOC, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-15-CC/ I and Receiver Selectivity Performance, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-16-C Blocking Performance, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-17-Cntermodulation Performance, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-18-C Maximum input signal level , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-19-C PER Report Integrity, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-20-C Receiver sensitivity at 2 Ms/s, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-21-C C/ I and Receiver Selectivity | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMS RTSB-A Test |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| Performance at 2 Ms/s, Stable Modulation Index | System | ||||
|---|---|---|---|---|---|
| RF-PHY/ RCV/BV-22-C Blocking performance at 2 Ms/s, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-23-CIntermodulation performance at 2 Ms/s, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-24-C Maximum input signal level at 2 Ms/s, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-25-C PER Report Integrity at 2 Ms/s, Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-26-C Receiver sensitivity, LE Coded (S=2) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-27-C Receiver sensitivity, LE Coded (S=8) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-28-CC/ I and Receiver Selectivity Performance, LE Coded (S=2) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-29-CC/ I and Receiver Selectivity Performance, LE Coded (S=8) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-30-C PER Report Integrity, LE Coded (S=2) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-31-C PER Report Integrity, LE Coded (S=8) | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-32-C Receiver sensitivity, LE Coded (S=2) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| RF-PHY/ RCV/BV-33-C Receiver sensitivity, LE Coded (S=8) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
|---|---|---|---|---|---|
| RF-PHY/ RCV/BV-34-CC/ I and Receiver Selectivity Performance, LE Coded (S=2) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-35-CC/ I and Receiver Selectivity Performance, LE Coded (S=8) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-36-C PER Report Integrity, LE Coded (S=2) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/BV-37-C PER Report Integrity, LE Coded (S=8) , Stable Modulation Index | Nominal | Nominal | Pass | 2021.05.14- 2021.06.01 | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-01-C IQ Samples Coherency, AoD Receiver at 1 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-02-C IQ Samples Coherency, AoD Receiver at 1 Ms/s with 1 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-03-C IQ Samples Coherency, AoD Receiver at 2 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-04-C IQ Samples Coherency, AoD Receiver at 2 Ms/s with 1 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-05-C IQ Samples Coherency, AoA Receiver at 1 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQC/BV-06-C IQ Samples Coherency, AoA Receiver at 2 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQDR/ BV-07-C IQ Samples Dynamic Range, | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMS RTSB-A Test |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| AoD Receiver at 1 Ms/s with 2 µs Slot | System | ||||
|---|---|---|---|---|---|
| RF-PHY/ RCV/ IQDR/ BV-08-C IQ Samples Dynamic Range, AoD Receiver at 1 Ms/s with 1 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQDR/ BV-09-C IQ Samples Dynamic Range, AoD Receiver at 2 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQDR/ BV-10-C IQ Samples Dynamic Range, AoD Receiver at 2 Ms/s with 1 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQDR/ BV-11-C IQ Samples Dynamic Range, AoA Receiver at 1 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
| RF-PHY/ RCV/ IQDR/ BV-12-C IQ Samples Dynamic Range, AoA Receiver at 2 Ms/s with 2 µs Slot | Nominal | Nominal | N/A | Not Required | CTTL-SYSTEMSRTSB-A Test System |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
Annex A. PICS & IXIT
Table 1 : Bluetooth LE RF Capabilities
| Item | Capability | Reference | Status | Support: YES or NO |
|---|---|---|---|---|
| 1/ 1 | LE Transmitter | [ 1] 3 | C.1 | YES |
| 1/2 | LE Receiver | [ 1] 4 | C.1 | YES |
| 1/3 | LE Transceiver | [ 1] 3 ,4 | C.1 | YES |
| 1/4 | LE 2M PHY | [3] 3 ,4 | C.2 | YES |
| 1/5 | Stable Modulation Index-Transmitter | [3] 3.1.1 | C.3 | YES |
| 1/6 | Stable Modulation Index-Receiver | [3] 3.1.1 | C.4 | YES |
| 1/7 | LE Coded PHY | [3] 3 ,4 | C.2 | YES |
| 1/8 | Transmitting Constant Tone Extensions | [4] 5 | C.3 | NO |
| 1/9 | 2 μs Antenna Switching During Constant Tone Extension Transmission (AoD) | [4] 5 | C.5 | NO |
| 1/ 10 | 1 μs Antenna Switching During Constant Tone Extension Transmission (AoD) | [4] 5 | C.6 | NO |
| 1/ 11 | 2 μs Antenna Sampling During Constant Tone Extension Reception (AoD) | [4] 5 | C.4 | NO |
| 1/ 12 | 2 μs Antenna Switching and Sampling During Constant Tone Extension Reception (AoA) | [4] 5 | C.7 | NO |
| 1/ 13 | 1 μs Antenna Sampling During Constant Tone Extension Reception (AoD) | [4] 5 | C.7 | NO |
| 1/ 14 | 1 μs Antenna Switching and Sampling During Constant Tone Extension Reception (AoA) | [2] 2 | C.8 | NO |
| 2/ 1 | HCI Test Interface | [2],2 | C.1 | YES |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| 2/2 | UART Test Interface | [2],3 | C.1 | YES |
|---|
C. 1:Mandatory to support at least one of these capabilities. Note that selecting both RF PHY 1/ 1 “LE Transmitter” and RF PHY 1/2 “LE Receiver” is equivalent to selecting RF PHY 1/3 “LE Transceiver” and vice versa.
C.2:Excluded IF SUM ICS 21/ 14 “Core v4 .2” is supported, otherwise Optional.
C.3 :Excluded IF SUM ICS 21/ 14 “Core v4 .2” is supported, otherwise Optional IF RF PHY 1/ 1 “LE Transmitter” OR RF PHY 1/3 “LE Transceiver” is supported, otherwise Excluded.
C.4:Excluded IF SUM ICS 21/ 14 “Core v4 .2” is supported, otherwise Optional IF RF PHY 1/2 “LE Receiver” OR RF PHY 1/3 “LE Transceiver” is supported, otherwise Excluded.
C.5 :Optional IF RF PHY 1/8 “Transmitting Constant Tone Extensions” is supported, otherwise Excluded.
C.6 :Optional IF RF-PHY 1/9 “2 μs Antenna Switching During Constant Tone Extension Transmission (AoD)” is supported, otherwise Excluded
C.7:Optional IF RF PHY 1/ 11 “2 μs Antenna Sampling During Constant Tone Extension Reception (AoD)” is supported, otherwise Excluded.
C.8 :Mandatory IF RF PHY 1/ 12 “2 μs Antenna Switching and Sampling During Constant Tone Extension Reception (AoA)” and RF/ PHY 1/ 13 “1 μs Antenna Sampling During Constant Tone Extension Reception (AoD)” are supported, otherwise Excluded.
C. 1: At least one of the capabilities shall be supported.
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
Table 2: Bluetooth LE RF PIXIT
| IXIT Reference | Identifier | Sub-Identifier (Optional) | Value | Units | Comments |
|---|---|---|---|---|---|
| RF-PHY:P1:1 | Inband Image frequency | Low frequency | 3 | MHz | RCV-LE/CA/03/C (C/ I and Receiver Selectivity Performance) |
| RF-PHY:P1:2 | Middle frequency | 3 | MHz | ||
| RF-PHY:P1:3 | High frequency | 3 | MHz | ||
| RF-PHY:P2:1 | Value n for Intermodul ation test | Low frequency | 5 | Integer | RCV-LE/CA/05/C ( Intermodulation Performance) |
| RF-PHY:P2:2 | Middle frequency | 5 | Integer | ||
| RF-PHY:P2:3 | High frequency | 5 | Integer | ||
| RF-PHY:P4 | Power source voltage | Nominal ( NOC) | 3.7 | V | Vol. 6 , Part A, Appendix A, Section A.1.2 , Nominal Supply Voltage |
| RF-PHY:P5 | Operating temperatur e | Nominal ( NOC) | 25 | °C | Vol. 6 , Part A, Appendix A, Section A.1.1 , Normal Temperature. The NOC test temperature shall be within ±10°C of this value. |
| RF-PHY:P6 :3 | Air humidity range (relative) | Air humidity level for NOC tests | 60 | % | Chapter 6.3.1 , Normal Temperature and Air Humidity |
| RF-PHY:P7:1 | Test interface implementa tion | HCI or 2-wire UART | HCI | / | Part F , Chapter 1 , Bluetooth Low Energy Controller Specification |
| RF-PHY:P7:2 | Datarate | 115200 | bps | Part F , Chapter 3.1 , Bluetooth Low Energy Controller Specification | |
| RF-PHY:P9 :1 | Maximum TX packet length( MA X_TX_LEN GTH) | 37 to 255 | 37 to 255 | Bytes | Chapter 6.7 , Bluetooth Low Energy RF-PHY Test Specification |
| RF-PHY:P9 :2 | Maximum RX packet length( MA X_RX_LEN GTH) | 37 to 255 | 37 to 255 | Bytes |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| RF-PHY:P9 :3 | Maximum TX packet length( MA X_TX_LEN GTH) 2M | 37 to 255 | 37 to 255 | Bytes | |
|---|---|---|---|---|---|
| RF-PHY:P9 :4 | Maximum TX packet length( MA X_TX_LEN GTH) S=2 | 37 to 255 | 37 to 255 | Bytes | |
| RF-PHY:P9 :5 | Maximum TX packet length( MA X_TX_LEN GTH) S=8 | 37 to 255 | 37 to 255 | Bytes | |
| RF-PHY:P9 :6 | Maximum RX packet length( MA X_RX_LEN GTH) 2M | 37 to 255 | 37 to 255 | Bytes | Chapter 6.7 , Bluetooth Low Energy RF-PHY Test Specification |
| RF-PHY:P9 :7 | Maximum RX packet length( MA X_RX_LEN GTH) S=2 | 37 to 255 | 37 to 255 | Bytes | |
| RF-PHY:P9 :8 | Maximum RX packet length( MA X_RX_LEN GTH) S=8 | 37 to 255 | 37 to 255 | Bytes | |
| RF-PHY:P10 : 1 | RF-PHY:P1 0 :1 | -20 to 10 (CSA5 unsupported) -20 to 20 (CSA5 supported) | 3 | dBm | Part A, Chapter 3 , Bluetooth Low Energy Controller Specification |
| RF-PHY:11:1 | Inband Image Frequency (2Ms/s) | Low frequency | 3 | MHz | RF-PHY/ RCV-LE/CA/ BV-09-C (C/ I and Receiver Selectivity Performance at 2Ms/s) |
| RF-PHY:11:2 | Middlefrequency | 3 | MHz | ||
| RF-PHY:11:3 | High frequency | 3 | MHz |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| RF-PHY:12:1 | Value n for Intermodul ation test (2Ms/s) | Low frequency | 5 | Integer | RF-PHY/ RCV-LE/CA/ BV-11-C ( Intermodulation performance at 2 Ms/s) |
|---|---|---|---|---|---|
| RF-PHY:12:2 | Middlefrequency | 5 | Integer | ||
| RF-PHY:12:3 | High frequency | 5 | Integer | ||
| RF-PHY:13 :1 | Inband Image Frequency (Stable Modulation Receiver) | Low frequency | 3 | MHz | RF-PHY/ RCV-LE/CA/ BV-15-C (C/ I and Receiver Selectivity Performance, Stable Modulation Index) |
| RF-PHY:13 :2 | Middlefrequency | 3 | MHz | ||
| RF-PHY:13 :3 | High frequency | 3 | MHz | ||
| RF-PHY:14:1 | Value n for Intermodul ation test (Stable Modulation Receiver) | Low frequency | 5 | Integer | RF-PHY/ RCV-LE/CA/ BV-17-C ( Intermodulation performance, Stable Modulation Index) |
| RF-PHY:14:2 | Middlefrequency | 5 | Integer | ||
| RF-PHY:14:3 | High frequency | 5 | Integer | ||
| RF-PHY:15 :1 | InbandIma ge Frequency (StableMod ulation Receiver , 2Ms/s) | Low frequency | 3 | MHz | RF-PHY/ RCV-LE/CA/ BV-21-C (C/ I and Receiver Selectivity Performance at 2Ms/s , Stable Modulation Index) |
| RF-PHY:15 :2 | Middlefrequency | 3 | MHz | ||
| RF-PHY:15 :3 | High frequency | 3 | MHz | ||
| RF-PHY:16 :1 | Value n for Intermodul ation test (Stable Modulation Receiver, 2Ms/s) | Low frequency | 5 | Integer | RF-PHY/ RCV-LE/CA/ BV-23-C ( Intermodulation performance at 2Ms/s , Stable Modulation Index) |
| RF-PHY:16 :2 | Middlefrequency | 5 | Integer | ||
| RF-PHY:16 :3 | High frequency | 5 | Integer | ||
| RF-PHY:17 | IQ Report Rate | 0x0006 to 0xFFFF | 0x0006 to 0xFFFF | / | TSPX_IQ_Report_Rate Indicates the rate of the IQ report generation. Advertising interval for periodic advertising = N * 1.25 ms , N = 0x0006-0xFFFF. Time Range: 7.5 ms- 81.91875 seconds. |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
| RF-PHY:18 | The length of the Constant Tone Extension( 1Ms/s) | 16 to 160 | 16 to 160 | bits | TSPX_CTE_len_max Vol. 6 , Part F , 4 , Section 4.1.7 , Constant Tone Extension |
|---|---|---|---|---|---|
| RF-PHY:19 | The length of the Constant Tone Extension( 2Ms/s) | 32 to 320 | 32 to 320 | bits | TSPX_CTE_len_max Vol. 6 , Part F , 4 , Section 4.1.7 , Constant Tone Extension |
| RF-PHY:20 | The number of antennae | / | ≥1 | / | TSPX_number_of_antennae |
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
Annex B. TEST SYSTEM
| Equipment Name | Serial No. | Type | Manufacturer | Cal Date | Due Date |
|---|---|---|---|---|---|
| CTTL-SYSTEMS-RTSB-A Test System | |||||
| Spectrum Analyser | MY53120346 | N9030A | Keysight | 2020.07.27 | 2021.07.26 |
| RF Signal Generator | MY45095851 | E4438C | Agilent | 2021.03.25 | 2022.03.24 |
| Wideband Generator | MY47461226 | E8257D | Agilent | 2021.03.25 | 2022.03.24 |
| Signalling Unit | 6 K00005351 | MT8852B | Anritsu | 2020.10.28 | 2021.10.27 |
| Industrial PC | -- | TEMPEL | Advantech | -- | -- |
| RTSB-A Switch Unit | -- | RTSB-A | CTTL | -- | -- |
| RF Tester Software | -- | SW ver. 3.0.0 | CTTL | -- | -- |
Annex C. TEST SETUP
CTTL-SYSTEMS-RTSB-A Test System
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
Annex D. EUT PHOTO

***** END OF REPORT ****
MORLAB
Shenzhen Morlab Communications Technology Co. , Ltd.
1-3/F, Building A, FeiYang Science Park, No.8 LongChang Road , Zone 67 , Baocheng , Bao’an District , ShenZhen , GuangDong , China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn